Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.
I agree, do not show this message again.EXCIMER EMISSION FROM THICK MICROHOLLOW CATHODE DISCHARGES IN XENON
L. D. Biborosch1,* , I. Petzenhauser2, S. Popescu1, Byung-Joon Lee2, K. Frank2
Affiliation
- Department of Plasma Physics, Al. I. Cuza-University, R-700506 Iasi, Romania
- Physics Department I, F. A.-University of Erlangen-Nueremberg, D-91058 Erlangen, Germany
Abstract
The vacuum ultraviolet emission was investigated end-on from the anode and cathode sides of a relatively thick microhollow cathode discharge. For this geometry and high xenon pressures the integral intensity measured from the anode side becomes comparable with that from the cathode side. Also, the excimer spectra corresponding to the two electrode sides are not so different as in the case of standard thin microhollow cathodes or with plane geometry. The homogeneous negative glow plasmas, which are now retained into the thick microhollow cathode, can explain this behavior..
Keywords
Microhollow cathode discharges, High pressure, Excimer radiation.
Submitted at: Jan. 21, 2005
Accepted at: Sept. 22, 2005
Citation
L. D. Biborosch, I. Petzenhauser, S. Popescu, Byung-Joon Lee, K. Frank, EXCIMER EMISSION FROM THICK MICROHOLLOW CATHODE DISCHARGES IN XENON, Journal of Optoelectronics and Advanced Materials Vol. 7, Iss. 5, pp. 2455-2458 (2005)
- Download Fulltext
- Downloads: 18 (from 16 distinct Internet Addresses ).