Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.

I agree, do not show this message again.

MICROSCOPIC ANALYSIS OF SINTERED TITANIUM-HYDROXYAPATITE IMPLANT MATERIALS

V. Simon1,* , D. Muresan1, C. Popa2, S. Simon1

Affiliation

  1. Babes-Bolyai University, Faculty of Physics, Cluj-Napoca 400084, Romania
  2. Technical University of Cluj-Napoca, Faculty of Materials Science and Engineering, Cluj-Napoca 400020, Romania

Abstract

A new system of functionally graded materials is considered in this study. The samples were obtained by sintering titanium with hydroxyapatite powders. Hydoxyapatite type grains were prepared by sol-gel method. The sintering conditions lead to convenient values of samples density as compared with bone density. The bioactivity was tested in simulatated body fluid (SBF). The size of hydroxyapatite type phases developed at the sample surface after soaking for a week in SBF is about hundreds of micrometers and tend to form a continuous network of the new developed bioactive layer..

Keywords

Sintered titanium-hydroxyapatite, Bioactive implant materials, Surface structure.

Submitted at: Aug. 22, 2005
Accepted at: Nov. 24, 2005

Citation

V. Simon, D. Muresan, C. Popa, S. Simon, MICROSCOPIC ANALYSIS OF SINTERED TITANIUM-HYDROXYAPATITE IMPLANT MATERIALS, Journal of Optoelectronics and Advanced Materials Vol. 7, Iss. 6, pp. 2823-2826 (2005)