Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.

I agree, do not show this message again.

NUMERICAL MODELLING OF NON-CONVENTIONAL SHIELDING

A. Razicheanu1, V. Ionita1,* , H. Gavrila1

Affiliation

  1. MAGNAT Research Center, University “Politehnica” of Bucharest, Spl. Independentei-313, 060042 - Bucharest, Romania

Abstract

A non-conventional shielding solution, with useful applications in civil engineering, is presented. The composite based on ferrimagnetic garnets from chemical plant residuals is analysed in a room-shaped geometry and the influence of some parameters (frequency, thickness of the shield layer, applied magnetic field, configuration of the room walls) is studied. The experimental and numerical data show the effectiveness of this ecological and low-cost shielding solution..

Keywords

Electromagnetic shielding, Ferrimagnetic garnets, Numerical modelling.

Submitted at: April 15, 2004
Accepted at: June 22, 2004

Citation

A. Razicheanu, V. Ionita, H. Gavrila, NUMERICAL MODELLING OF NON-CONVENTIONAL SHIELDING, Journal of Optoelectronics and Advanced Materials Vol. 6, Iss. 3, pp. 1009-1012 (2004)