Our site saves small pieces of text information (cookies) on your device in order to deliver better content and for statistical purposes. You can disable the usage of cookies by changing the settings of your browser. By browsing our site without changing the browser settings you grant us permission to store that information on your device.

I agree, do not show this message again.

Electrochemical corrosion characteristics of TiTa alloys in commercial mouthwash solution

D. MARECI1, R. CHELARIU2, G. BOLAT1, A. CAILEAN1, D. SUTIMAN1,*

Affiliation

  1. “Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, 73 Mangeron Blvd., 700050, Iasi, Romania
  2. “Gheorghe Asachi” Technical University of Iasi, Faculty of Materials Science and Engineering, 61A Mangeron Blvd., 700050, Iasi, Romania

Abstract

Corrosion behaviour of the studied TiTa alloys together with the currently used metallic biomaterials commercial pure titanium (Cp-Ti) was investigated for dental applications. All the samples were examined using electrochemical techniques: open circuit potential, potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS) in two electrochemical media: artificial saliva and in commercial mouthwash solution with 500 ppm F- (Oral B® , Gillette) at 25o C. The passive behaviour for all the Ti samples is observed for artificial saliva and for commercial mouthwash solution. The TiTa alloys appear to posse’s superior corrosion resistance than the Cp-Ti in both electrochemical media..

Keywords

TiTa samples, Potentiodynamic polarization, Electrochemical impedance spectroscopy.

Submitted at: Dec. 15, 2011
Accepted at: Feb. 20, 2012

Citation

D. MARECI, R. CHELARIU, G. BOLAT, A. CAILEAN, D. SUTIMAN, Electrochemical corrosion characteristics of TiTa alloys in commercial mouthwash solution, Journal of Optoelectronics and Advanced Materials Vol. 14, Iss. 1-2, pp. 112-119 (2012)